Savenas

General Information

Savenas
ENLARGE ENLARGE IMAGE

Owner: Renova AB
Operator: Renova AB
City: Gothenburg
Country: Sweden
Startup Date/Year: 12/31/1993
PLANT WEB SITE External Site

Waste-to-Energy Process
Technology: Mass-Burn
Number of process lines: 3
Primary fuel: Municipal Solid Waste
Secondary fuel: Oil
Treatment capacity: 460,000 tonnes/annum
Pollution Prevention and Control
AIR POLLUTION CONTROL EQUIPMENT:
  • Activated Carbon Injection
  • Dry Scrubber
  • Electrostatic Precipitator
  • Selective Non-Catalytic Reduction
Energy Production
Electricity Production: 263 GWh/annum
Heat Production: 350 GWh/annum
Prime Mover: Steam Turbine